Direction:
Escuela de Ingenierías Industriales. Paseo del Cauce, 59 47011 ValladolidFecha: 30/04/2013
Contact:
José Antonio Domínguez Vázquez983 184 700
josdom@eii.uva.es
Escuela de Ingenierías Industriales. Paseo del Cauce, 59 47011 Valladolid
Presentation
Ubication: Escuela de Ingenierías Industriales. Paseo del Cauce, 59 47011 ValladolidYear of creation: 1991
Description:Calibration laboratory (Electricity, Time and frequency, Power and energy). Electrical Testing Laboratory (electrical security, Electromagnetic compatibility).
supports visits: Si
Function Microred: No [2]
Island funtion: No
TYPE OF SERVICES:
- Laboratory
- Legal Metrology Laboratory (energy meters, transformers)
- R&D department (LACECAL I+D).
- Training department.
[1] It is understood that managed power that is able to manage the control of the infrastructure. In laboratories without physical equipment (simulators, systems) This field does not apply.
[2] Microrred function if there are loads in the same location, generators and optionally storage, with integrated management of the whole.
EQUIPMENT
Consumer equipment
Type of load |
Voltage level |
Power |
Connection type |
Single phase resistors bench |
LV |
30KW |
Manual |
Configurable resistors bench single/three-phase |
LV |
10KW |
Manual |
Grid connected inverter with working as programmable load capacity-CMMmodel (Owndesign) |
LV |
25KW |
Electronic |
Grid connected inverter with working as programmable load capacity-CEB-H2mode l(Owndesign) |
LV |
3KW |
Electronic |
Storage Equipment
Storage technology |
Voltage level |
Energy |
Connection type |
Pack of lead-acid batteries |
LV |
3.5KWh |
Electronic |
Pack of LiFe PO 4 batteries |
LV |
2.8KWh |
Electronic |
Power control equipment
Power electronics |
|
|
Type |
Voltage level |
Power |
CMM three-phase inverter-own design (FACTS functionality) |
LV |
25KW |
CEB-H2 three-phase inverter-own design (FACTS functionality) |
LV |
3KW |
VENTU Sthree-phase wind turbine regulator-own design |
LV |
3KW |
Generation control equipment
Generation technology |
Voltage level |
Power |
Connection type |
Photovoltaic system on roof |
LV |
20KW |
Electronic |
Wind turbine |
LV |
1KW |
Electronic |
DC power supply |
1000V |
15KW |
|
Simulation control equipment
Control algorithms |
|
Type |
Description |
Soft.Simulation |
MATLAB/ SIMULINK |
Soft.CAD |
Electronic CAD different environments |
OTHERS
- Network quality analysers.
- High voltage cell for transformer testing.
- Benches for the dielectric strength testing.
- Rantec Anechoic chamber.
- Electrostatic discharge Emulators.
- Emulators for immunity testing (Conducted and radia- ted).
- Equipment for harmonics and flicker testing.
- Environmental chamber.
- Photovoltaic generators characterization equipment.
- Thermographic Camera
KNOWLEDGE
Academic qualification |
Number of Professionals |
Average experience years |
Knowledge areas |
Dr.Engineer |
2 |
26 |
RES,VE,EPOT,CI,TIC |
Senior engineer |
3 |
23 |
RES,VE,EPOT,CI,TIC |
Technical engineer |
7 |
15 |
RES,VE,EPOT,CI,TIC |
Professional training |
4 |
6 |
RES,VE,EPOT,CI,TIC |
Grantees
Knowledge area: RES, VE, EPOT, CI, TIC
Average number per year: 2
Others (Final project, master, etc.)
Knowledge area4: RES, VE, EPOT, CI, TIC
Average number per year: 3
Knowledge areas: Demand Management (GD), integration of renewable and distributed energy resources (RES), protection and network automation (AUTO), electric vehicle (EV), power electronics (EPOT), storage ( BAT), sensors (SEN), life management (lIFE), smart meters (CI), transformers (TRAFO), conductors (CABLE), information and communication technologies (ICT)
PROJECTS
Acronym-Name |
Ambit |
Initial/end year |
Total budget |
Knowledge area |
JOR3-CT98-7005 |
European |
1999-2003 |
714.158ECU |
RES |
PROFIT-020100-2003-354 |
National |
2003-2003 |
86.945€ |
CIR |
PROFIT-020400-2004-39 |
National |
2004-2004 |
93.799€ |
CIR |
PROFIT-020400-2005-199 |
National |
2005-2005 |
95.900€ |
EPOT |
PROFIT-120000-2005-23 |
National |
2005-2005 |
286.340€ |
RES,EPOT |
PROFIT-120000-2006-138 |
National |
2006-2007 |
195.876€ |
RES,EPOT |
PROFIT-120000-2007-100 |
National |
2007-2007 |
354.347€ |
RES,EPOT |
ADE04/06/LE/007 |
Regional |
2006-2007 |
500.790€ |
RES,EPOT |
ADE04/07/LE/003 |
Regional |
2007-2008 |
297.974€ |
RES,EPOT |
ADE05/08/VA/55 |
Regional |
2009-2010 |
873.379€ |
RES,EPOT |
ADE05/08/VA/56 |
Regional |
2009-2010 |
877.603€ |
RES,EPOT,VE |
[5] Regional, National, European, …