Direction:
Paseo de Arizmendiarreta, 2 20500 Mondragón (Guipúzcoa)Fecha: 30/04/2013
Contact:
Francisco J. Blanco Barro943217400
fjblanco@ikerlan.es
Paseo de Arizmendiarreta, 2 20500 Mondragón (Guipúzcoa)
Presentation
Ubication: Paseo de Arizmendiarreta, 2 20500 Mondragón (Guipúzcoa)Year of creation: 2010
managed power: 300 kW[1]
Description:This a laboratory that covers the entire value chain for the development of power storage systems to be applied in grids and in the transport sector.
supports visits: Si
Function Microred: No [2]
Island funtion: No
TYPE OF SERVICES:
- Laboratory
[1] It is understood that managed power that is able to manage the control of the infrastructure. In laboratories without physical equipment (simulators, systems) This field does not apply.
[2] Microrred function if there are loads in the same location, generators and optionally storage, with integrated management of the whole.
EQUIPMENT
Storage Equipment
Storage technology |
Voltage level |
Power |
Connection type |
2 Digatron MCT cell cyclers with 10 channels each and voltages ranging from 0 to 6 Vand an intensity of 0 to 100 A |
0-6V |
17kVA (25A) |
3NPE400V/50Hz |
1 Digatron MCT cell cycler with 24 channels and voltages ranging from 0 to 6 V and a nintensity of 0 to 50 A. |
0-6V |
19.5kVA (28A) |
3NPE400V/50Hz |
1 Digatron cycler with BNT modules, 2 channels and voltages ranging from 0 to100 V and an intensity of 0 to100 A |
6-100V |
23.5kVA (34A) |
3NPE400V/50Hz |
1 cell cycler with small CADEX modules,4 channels and voltages ranging from 0 to 30 V and an intensity of 0 to 10 A |
0-30V |
400W incharge 320Windischarge |
1NPE230V/50Hz |
1 BK 8510 electronic load compatible with CADEX, with 120 V and 120 A |
120V |
600W |
1NPE230V/50Hz |
1 Digatron EVT/IGBT battery pack cycler with 1 channel and voltages ranging from 0 to 600 V and anintensity of 0 to 300 A |
0-600V |
95kVA |
3NPE400V/50Hz |
1 Digatron EI Smeter with 4 channels and voltages ranging from 0 to 20 V and anintensity of+/-2AAC |
0-20V |
65 W/channel |
1NPE230V/50Hz |
1 Digatron data logger with 36 channels and voltages ranging from 0 to 5V |
0-5V |
100VA (0.5A) |
1NPE230V/50Hz |
OTHERS
- 6 Prebatem heaters from the commercial firm Selecta with a temperature range of 0 °C to 50 °C for performing tests at room temperature. These heaters have no safety means but are intended to act as a temperature conditioning system for tests at room temperature.
- 1 calorimeter from the commercial firm THT for measuring the heat generated by batte- ries in charging and discharging processes.
- A firm for testing monitoring systems (30).
- Natural gas, propane and diesel supplies.
- System for refrigeration by absorption (31).
- Thermal-solar support system with 10 kW of power.
- Solar photovoltaic system with 3 kW of peak power.
- Photovoltaic facility (Ecotecnia, 2 kWe. Single-phase).
- Micro-turbine (Capstone, 30 kWe / 85 kWth. Three-phase).
- Stirling Engine (Solo, 9.5 kWe, 26 kWth. Three-phase).
- Storage system (Sunny Island 15 kW. Three-phase).
- Controllable domotic load system (Fagor domestic appliances).
- Measurement and protection system (ZIV).
- Monitoring, control and management system.
- QNA 512 by CIRCUITOR - Power analysers.
- Wavebook 516 by IOTECH - Data gathering system.
- RPM (Recorder Power Meter) by ADLER.
- 15 kW Profline three-phase grid simulator.
- Fuel cell testing system.
- Natural gas, hydrogen and mixed gas supplies.
- Adjustable electronic load.
- Solartron impedance analyser.
KNOWLEDGE
Academic qualification |
Number of Professionals |
Average experience years |
Knowledge areas |
Doctor |
15 |
10 |
BAT,EPOT,RES |
Engineers |
22 |
15 |
BAT,EPOT,RES |
Graduates |
10 |
15 |
BAT,EPOT,RES |
Doctorate students
Knowledge areas |
Average number per year |
BAT |
8 |
EPOT |
6 |
RES |
4 |
Others (Final project, master, etc)
Knowledge areas |
Average number per year |
BAT |
12 |
Knowledge areas: Demand Management (GD), integration of renewable and distributed energy resources (RES), protection and network automation (AUTO), electric vehicle (EV), power electronics (EPOT), storage ( BAT), sensors (SEN), life management (lIFE), smart meters (CI), transformers (TRAFO), conductors (CABLE), information and communication technologies (ICT)
PROJECTS
Acronym-Name |
Ambit |
Initial/end year |
Total budget |
Knowledge areas |
Etortek2010 |
Regional |
2010-2012 |
3.500.000€ |
(BAT) |
Etortek2012 |
Regional |
2011-2013 |
3.700.000€ |
(BAT) |
Etortek2013 |
Regional |
2012-2014 |
3.900.000€ |
(BAT) |
Emaitek2010 |
Regional |
2010 |
750.000€ |
BAT) |
Emaitek2011 |
Regional |
2010 |
8.750.000€ |
(BAT) |
Emaitek2012 |
Regional |
2010 |
9.500.000€ |
(BAT) |
Batteries2020 |
European |
2013-2016 |
9.000.000€ |
Electricstorage |
Reemain |
European |
2013-2017 |
12.000.000€ |
(BAT) |
[5] Regional, National, European, …